Quiz-summary
0 of 10 questions completed
Questions:
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
Information
Premium Practice Questions
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 10 questions answered correctly
Your time:
Time has elapsed
Categories
- Not categorized 0%
Unlock Your Full Report
You missed {missed_count} questions. Enter your email to see exactly which ones you got wrong and read the detailed explanations.
Submit to instantly unlock detailed explanations for every question.
Success! Your results are now unlocked. You can see the correct answers and detailed explanations below.
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- Answered
- Review
-
Question 1 of 10
1. Question
An internal review at a wealth manager examining Emergency response to hazardous materials incidents as part of market conduct has uncovered that during a safety audit of a remote data center, the fire protection engineers identified a discrepancy in the predicted heat release rate (HRR) for a potential spill of a specific hydrocarbon-based coolant. The audit noted that the fluid’s high heat of vaporization was not properly factored into the emergency response timelines for manual intervention. Which of the following best describes the impact of a high heat of vaporization on the fire’s development in this scenario?
Correct
Correct: Heat of vaporization is the amount of energy required to transform a unit mass of a substance from a liquid to a gas at a constant temperature. In the context of fire dynamics, liquid fuels do not burn directly; they must be vaporized first. A high heat of vaporization means that more of the thermal energy produced by the fire (or provided by an external ignition source) is used to vaporize the fuel rather than heating the surrounding environment or increasing the temperature of the liquid, thereby slowing the rate of vapor production and the overall heat release rate (HRR).
Incorrect: Lowering the flammability limit (LFL) is a function of the chemical structure of the vapor and its concentration in air, not the energy required for phase change. Minimum ignition energy (MIE) refers to the smallest amount of energy required to ignite a flammable vapor-air mixture and is not directly reduced by a high heat of vaporization; in fact, high vaporization energy requirements generally make ignition more difficult. The transition between diffusion and pre-mixed flames is determined by whether the fuel and oxidizer are mixed before or during the combustion process, not by the fuel’s heat of vaporization.
Takeaway: The heat of vaporization is a critical fuel property that dictates the energy balance of a fire, where higher values act as a thermal sink that slows the rate of gasification and fire growth.
Incorrect
Correct: Heat of vaporization is the amount of energy required to transform a unit mass of a substance from a liquid to a gas at a constant temperature. In the context of fire dynamics, liquid fuels do not burn directly; they must be vaporized first. A high heat of vaporization means that more of the thermal energy produced by the fire (or provided by an external ignition source) is used to vaporize the fuel rather than heating the surrounding environment or increasing the temperature of the liquid, thereby slowing the rate of vapor production and the overall heat release rate (HRR).
Incorrect: Lowering the flammability limit (LFL) is a function of the chemical structure of the vapor and its concentration in air, not the energy required for phase change. Minimum ignition energy (MIE) refers to the smallest amount of energy required to ignite a flammable vapor-air mixture and is not directly reduced by a high heat of vaporization; in fact, high vaporization energy requirements generally make ignition more difficult. The transition between diffusion and pre-mixed flames is determined by whether the fuel and oxidizer are mixed before or during the combustion process, not by the fuel’s heat of vaporization.
Takeaway: The heat of vaporization is a critical fuel property that dictates the energy balance of a fire, where higher values act as a thermal sink that slows the rate of gasification and fire growth.
-
Question 2 of 10
2. Question
In your capacity as portfolio manager at an insurer, you are handling Mutual aid and interagency cooperation during whistleblowing. A colleague forwards you an incident report showing that during a multi-jurisdictional response to a 50,000 square foot logistics center fire, a lack of shared technical data regarding the high-piled plastic storage led to a catastrophic flashover. The whistleblower alleges that the responding units failed to synchronize their assessment of the fuel’s heat release rate (HRR) and the building’s ventilation state. Which technical principle should have been the primary focus of the unified command to predict and mitigate the flashover risk?
Correct
Correct: Flashover is a transition phase in a compartment fire where all exposed fuel surfaces ignite nearly simultaneously. This is primarily driven by the heat release rate (HRR) of the fire, which increases the temperature of the upper gas layer. As this layer thickens and gets hotter, it radiates energy back down to the floor-level contents. When the radiant heat flux reaches a critical level (typically around 20 kW/m2), flashover occurs. In a mutual aid scenario, interagency cooperation must prioritize sharing data on HRR and ventilation to manage this risk.
Incorrect: The autoignition temperature of structural steel is not a factor in flashover, as steel does not ignite; its structural integrity is a separate concern. Chemical kinetics of the combustion reaction describes the rate of reaction at a molecular level but is too granular for predicting compartment-scale flashover. Thermal conductivity of the flooring has a negligible impact on the heat of vaporization of the fuel compared to the massive radiant energy provided by the hot gas layer during the growth phase of a fire.
Takeaway: Predicting flashover in large-scale incidents requires interagency coordination focused on the heat release rate and the resulting radiant heat flux from the upper thermal layer.
Incorrect
Correct: Flashover is a transition phase in a compartment fire where all exposed fuel surfaces ignite nearly simultaneously. This is primarily driven by the heat release rate (HRR) of the fire, which increases the temperature of the upper gas layer. As this layer thickens and gets hotter, it radiates energy back down to the floor-level contents. When the radiant heat flux reaches a critical level (typically around 20 kW/m2), flashover occurs. In a mutual aid scenario, interagency cooperation must prioritize sharing data on HRR and ventilation to manage this risk.
Incorrect: The autoignition temperature of structural steel is not a factor in flashover, as steel does not ignite; its structural integrity is a separate concern. Chemical kinetics of the combustion reaction describes the rate of reaction at a molecular level but is too granular for predicting compartment-scale flashover. Thermal conductivity of the flooring has a negligible impact on the heat of vaporization of the fuel compared to the massive radiant energy provided by the hot gas layer during the growth phase of a fire.
Takeaway: Predicting flashover in large-scale incidents requires interagency coordination focused on the heat release rate and the resulting radiant heat flux from the upper thermal layer.
-
Question 3 of 10
3. Question
Serving as compliance officer at an audit firm, you are called to advise on Emergency response to hazardous materials incidents during client suitability. The briefing a policy exception request highlights that a manufacturing client has introduced a new solvent into their production line that possesses a significantly higher Heat Release Rate (HRR) than the previous material, despite having a similar heat of combustion. The client’s safety officer suggests that the existing fire suppression and emergency evacuation timelines are still valid because the total fuel load remains unchanged. Based on fire dynamics principles, how should the audit team evaluate the impact of the increased HRR on the facility’s emergency response capabilities?
Correct
Correct: The Heat Release Rate (HRR) is the most critical variable in fire hazard assessment as it dictates the rate of energy release. A higher HRR means the fire will grow more rapidly, reducing the time available for occupants to evacuate and for emergency responders to intervene. It also determines the required cooling capacity of suppression systems; a fire that releases energy faster requires a higher application rate of extinguishing agents to overcome the heat generation, regardless of the total potential energy (heat of combustion) available.
Incorrect: Focusing on the heat of combustion is incorrect because it only measures the total energy available, not the speed of its release, which is what determines the fire’s immediate threat. Minimum ignition energy (MIE) refers to the energy required to start a fire, not its behavior after ignition. Autoignition temperature is the temperature at which a substance ignites without a pilot source, but it does not govern the fire’s growth rate or the intensity that suppression systems must combat once the fire is established.
Takeaway: Heat Release Rate (HRR) is the primary determinant of fire severity and dictates the necessary speed and capacity of both manual and automatic fire protection responses.
Incorrect
Correct: The Heat Release Rate (HRR) is the most critical variable in fire hazard assessment as it dictates the rate of energy release. A higher HRR means the fire will grow more rapidly, reducing the time available for occupants to evacuate and for emergency responders to intervene. It also determines the required cooling capacity of suppression systems; a fire that releases energy faster requires a higher application rate of extinguishing agents to overcome the heat generation, regardless of the total potential energy (heat of combustion) available.
Incorrect: Focusing on the heat of combustion is incorrect because it only measures the total energy available, not the speed of its release, which is what determines the fire’s immediate threat. Minimum ignition energy (MIE) refers to the energy required to start a fire, not its behavior after ignition. Autoignition temperature is the temperature at which a substance ignites without a pilot source, but it does not govern the fire’s growth rate or the intensity that suppression systems must combat once the fire is established.
Takeaway: Heat Release Rate (HRR) is the primary determinant of fire severity and dictates the necessary speed and capacity of both manual and automatic fire protection responses.
-
Question 4 of 10
4. Question
Excerpt from a regulator information request: In work related to Tactics for different fire types (structure fires, wildland fires, vehicle fires) as part of record-keeping at an insurer, it was noted that several high-value property losses were attributed to a failure to recognize the transition from fuel-controlled to ventilation-controlled combustion. During a review of the 2023 incident response reports, it was found that tactical decisions did not account for the accumulation of unburned pyrolyzates in the upper gas layer. Based on fire dynamics principles, which of the following statements correctly distinguishes the tactical considerations between these fire environments?
Correct
Correct: In a compartmented structure fire, the fire often consumes oxygen faster than it can be replenished through openings, leading to a ventilation-controlled state. In this state, the heat release rate is limited by the available air, and introducing fresh air (ventilation) without cooling the accumulated hot gases can lead to rapid fire growth or flashover. Conversely, wildland fires occur in the open where oxygen is essentially unlimited, meaning the fire’s growth and intensity are limited by the fuel characteristics (moisture content, type) and environmental factors like wind and slope, making them fuel-controlled.
Incorrect: Option b is incorrect because wildland fires are almost always fuel-controlled due to the open atmosphere; oxygen is not the limiting factor. Option c is incorrect because vehicle fires, like any other fire, are governed by the laws of thermodynamics and oxygen availability; while metal conducts heat, the heat release rate is still heavily influenced by ventilation and fuel geometry. Option d is incorrect because modern synthetic materials have high heat release rates that actually deplete oxygen faster, causing structure fires to reach a ventilation-controlled state much more quickly than fires involving legacy natural materials.
Takeaway: Understanding whether a fire is fuel-controlled or ventilation-controlled is essential for determining whether to prioritize air-flow management or fuel-load reduction.
Incorrect
Correct: In a compartmented structure fire, the fire often consumes oxygen faster than it can be replenished through openings, leading to a ventilation-controlled state. In this state, the heat release rate is limited by the available air, and introducing fresh air (ventilation) without cooling the accumulated hot gases can lead to rapid fire growth or flashover. Conversely, wildland fires occur in the open where oxygen is essentially unlimited, meaning the fire’s growth and intensity are limited by the fuel characteristics (moisture content, type) and environmental factors like wind and slope, making them fuel-controlled.
Incorrect: Option b is incorrect because wildland fires are almost always fuel-controlled due to the open atmosphere; oxygen is not the limiting factor. Option c is incorrect because vehicle fires, like any other fire, are governed by the laws of thermodynamics and oxygen availability; while metal conducts heat, the heat release rate is still heavily influenced by ventilation and fuel geometry. Option d is incorrect because modern synthetic materials have high heat release rates that actually deplete oxygen faster, causing structure fires to reach a ventilation-controlled state much more quickly than fires involving legacy natural materials.
Takeaway: Understanding whether a fire is fuel-controlled or ventilation-controlled is essential for determining whether to prioritize air-flow management or fuel-load reduction.
-
Question 5 of 10
5. Question
The operations team at a wealth manager has encountered an exception involving Limitations of fire modeling during control testing. They report that during a comprehensive risk evaluation of their flagship high-rise headquarters, the fire modeling software used to predict smoke movement failed to align with the results of a physical smoke tracer test conducted on the 15th floor. The audit team noted that the model, which utilized a standard computational fluid dynamics (CFD) approach, did not accurately predict the stratification of smoke in the large atrium area. When assessing the validity of fire models for such complex environments, which of the following best describes a fundamental limitation regarding the input and processing of fire dynamics?
Correct
Correct: A primary limitation of fire modeling is the simplification of combustion chemistry. Most models, including sophisticated CFD (field) models, do not solve the full set of chemical kinetic equations for every species. Instead, they often rely on user-defined ‘yields’ (e.g., soot yield, CO yield) which are based on empirical data from well-ventilated experiments. In reality, as a fire becomes under-ventilated (oxygen-limited), the chemical pathways change significantly, leading to different rates of toxic product generation that the model may not capture accurately.
Incorrect: The assertion that models cannot account for radiation is incorrect, as radiation is a core component of the energy balance in both zone and field models. The claim that models are limited only to pre-flashover conditions is false; many models are specifically designed to simulate the transition to flashover and post-flashover behavior. Finally, modern fire models absolutely allow for the input of thermophysical properties of boundary materials, such as thermal conductivity and specific heat, to calculate heat loss through walls and ceilings.
Takeaway: Fire models are limited by their simplified treatment of complex chemical kinetics and their reliance on empirical species yield data, especially in under-ventilated fire scenarios.
Incorrect
Correct: A primary limitation of fire modeling is the simplification of combustion chemistry. Most models, including sophisticated CFD (field) models, do not solve the full set of chemical kinetic equations for every species. Instead, they often rely on user-defined ‘yields’ (e.g., soot yield, CO yield) which are based on empirical data from well-ventilated experiments. In reality, as a fire becomes under-ventilated (oxygen-limited), the chemical pathways change significantly, leading to different rates of toxic product generation that the model may not capture accurately.
Incorrect: The assertion that models cannot account for radiation is incorrect, as radiation is a core component of the energy balance in both zone and field models. The claim that models are limited only to pre-flashover conditions is false; many models are specifically designed to simulate the transition to flashover and post-flashover behavior. Finally, modern fire models absolutely allow for the input of thermophysical properties of boundary materials, such as thermal conductivity and specific heat, to calculate heat loss through walls and ceilings.
Takeaway: Fire models are limited by their simplified treatment of complex chemical kinetics and their reliance on empirical species yield data, especially in under-ventilated fire scenarios.
-
Question 6 of 10
6. Question
How can Maintenance of smoke control systems be most effectively translated into action? When evaluating the maintenance program for a smoke management system designed to maintain tenable conditions based on a specific design fire’s heat release rate (HRR), which action provides the most reliable evidence that the system will successfully manage smoke buoyancy during an event?
Correct
Correct: Integrated functional testing is the only method that verifies the system as a whole can produce the necessary pressure differentials and exhaust volumes to counteract the buoyancy of a smoke plume generated by the design fire. This ensures the system meets the performance requirements established during the fire dynamics analysis and maintains the required clear height.
Incorrect
Correct: Integrated functional testing is the only method that verifies the system as a whole can produce the necessary pressure differentials and exhaust volumes to counteract the buoyancy of a smoke plume generated by the design fire. This ensures the system meets the performance requirements established during the fire dynamics analysis and maintains the required clear height.
-
Question 7 of 10
7. Question
The monitoring system at a broker-dealer has flagged an anomaly related to Data centers during third-party risk. Investigation reveals that a high-density server rack in a colocation facility has experienced a localized overheating event characterized by a prolonged period of non-flaming combustion within the cable management system. The facility manager reports that while the Very Early Warning Smoke Detection (VEWSD) system alerted the operations team, there was no immediate evidence of a visible flame or significant temperature spike in the hot aisle. Given the characteristics of the materials involved, such as PVC or plenum-rated cable jackets, which fire behavior phenomenon is occurring and what is the primary concern regarding its development?
Correct
Correct: The scenario describes smoldering combustion, which is a slow, low-temperature, flameless form of combustion that occurs on the surface of solid fuels. In data centers, this is common with electrical components and cable insulation. The primary risk is that smoldering can produce significant amounts of toxic and corrosive smoke (which can damage sensitive electronics) and can eventually transition into a flaming fire if the heat release rate (HRR) increases or if there is a change in the oxygen supply/ventilation.
Incorrect: Flashover is a specific stage in compartment fire development where all combustible surfaces in a room ignite simultaneously; it is not a localized non-flaming event. Pre-mixed flame propagation involves the combustion of a fuel and oxidizer that are mixed prior to ignition, which does not apply to the surface-level charring of solid cable insulation. Autoignition refers to the initiation of combustion by heat alone without an external spark or flame, but the scenario describes a process already in progress (non-flaming combustion) rather than the mechanism of initial ignition.
Takeaway: Smoldering combustion is a critical early-stage fire hazard in data centers that requires specialized detection because it lacks the high heat release rate and visible flame of traditional fires.
Incorrect
Correct: The scenario describes smoldering combustion, which is a slow, low-temperature, flameless form of combustion that occurs on the surface of solid fuels. In data centers, this is common with electrical components and cable insulation. The primary risk is that smoldering can produce significant amounts of toxic and corrosive smoke (which can damage sensitive electronics) and can eventually transition into a flaming fire if the heat release rate (HRR) increases or if there is a change in the oxygen supply/ventilation.
Incorrect: Flashover is a specific stage in compartment fire development where all combustible surfaces in a room ignite simultaneously; it is not a localized non-flaming event. Pre-mixed flame propagation involves the combustion of a fuel and oxidizer that are mixed prior to ignition, which does not apply to the surface-level charring of solid cable insulation. Autoignition refers to the initiation of combustion by heat alone without an external spark or flame, but the scenario describes a process already in progress (non-flaming combustion) rather than the mechanism of initial ignition.
Takeaway: Smoldering combustion is a critical early-stage fire hazard in data centers that requires specialized detection because it lacks the high heat release rate and visible flame of traditional fires.
-
Question 8 of 10
8. Question
The supervisory authority has issued an inquiry to a listed company concerning Classification of hazardous materials in the context of complaints handling. The letter states that multiple internal reports from the past 18 months indicate that the facility’s hazard classification system fails to account for the effects of elevated process temperatures on the behavior of flammable vapors. As part of a risk assessment to address these complaints, the fire protection specialist must determine how a significant increase in temperature affects the flammability limits of the stored gaseous fuels. Which of the following statements accurately describes this relationship?
Correct
Correct: The Lower Flammability Limit (LFL) is the minimum concentration of a combustible gas in air that can support flame propagation. As the temperature of the mixture increases, the LFL decreases. This is because the molecules already possess higher internal energy, meaning less energy must be released by the chemical reaction to reach the adiabatic flame temperature required for propagation. This effectively widens the flammable range (the gap between LFL and UFL), making the environment more hazardous.
Incorrect: Increasing the LFL would mean a higher concentration of fuel is needed for ignition, which is the opposite of what happens when temperature rises. While temperature does affect the heat of vaporization for liquids, it absolutely has a measurable effect on the LFL of gases. Finally, an increase in temperature typically decreases the Minimum Ignition Energy (MIE), making the substance easier to ignite, rather than more resistant.
Takeaway: Increasing the temperature of a flammable gas mixture lowers its Lower Flammability Limit (LFL), thereby increasing the fire risk by allowing ignition to occur at lower fuel concentrations.
Incorrect
Correct: The Lower Flammability Limit (LFL) is the minimum concentration of a combustible gas in air that can support flame propagation. As the temperature of the mixture increases, the LFL decreases. This is because the molecules already possess higher internal energy, meaning less energy must be released by the chemical reaction to reach the adiabatic flame temperature required for propagation. This effectively widens the flammable range (the gap between LFL and UFL), making the environment more hazardous.
Incorrect: Increasing the LFL would mean a higher concentration of fuel is needed for ignition, which is the opposite of what happens when temperature rises. While temperature does affect the heat of vaporization for liquids, it absolutely has a measurable effect on the LFL of gases. Finally, an increase in temperature typically decreases the Minimum Ignition Energy (MIE), making the substance easier to ignite, rather than more resistant.
Takeaway: Increasing the temperature of a flammable gas mixture lowers its Lower Flammability Limit (LFL), thereby increasing the fire risk by allowing ignition to occur at lower fuel concentrations.
-
Question 9 of 10
9. Question
What control mechanism is essential for managing Application of scientific principles to fire investigation? During a post-incident analysis of a residential structure fire, an investigator is evaluating the transition of the fire from its incipient stage to a fully developed state. The investigator notes that the fire reached flashover significantly faster than expected given the fuel load. To accurately reconstruct the fire’s timeline and behavior using the scientific method, the investigator must evaluate the relationship between the heat release rate (HRR) and the available oxygen. Which principle best explains the critical transition point where the fire’s growth becomes limited by the physical dimensions of the openings in the compartment rather than the characteristics of the fuel?
Correct
Correct: In fire dynamics, the transition from a fuel-controlled fire to a ventilation-controlled fire is a fundamental scientific principle used in fire investigation. A fuel-controlled fire is one in which the heat release rate is limited by the mass loss rate of the fuel. As the fire grows within a compartment, it eventually consumes oxygen faster than it can be replaced through openings. At this point, the fire becomes ventilation-controlled, meaning the heat release rate is limited by the amount of oxygen available for combustion. Understanding this transition is essential for investigators to explain fire patterns and the speed of fire development leading to flashover.
Incorrect: Calculating the minimum ignition energy is relevant to the ease of ignition of a substance but does not govern the transition to a ventilation-controlled state in a fully developed fire. Determining specific heat capacity is important for understanding how materials absorb heat, but it is not the primary mechanism that limits fire growth in a compartment. Autoignition temperature is the lowest temperature at which a substance will spontaneously ignite without an external spark or flame; while relevant to ignition, it does not define the transition from fuel-controlled to ventilation-controlled combustion.
Takeaway: Accurate fire reconstruction requires identifying whether a fire was fuel-controlled or ventilation-controlled to understand how oxygen availability influenced the heat release rate and fire spread.
Incorrect
Correct: In fire dynamics, the transition from a fuel-controlled fire to a ventilation-controlled fire is a fundamental scientific principle used in fire investigation. A fuel-controlled fire is one in which the heat release rate is limited by the mass loss rate of the fuel. As the fire grows within a compartment, it eventually consumes oxygen faster than it can be replaced through openings. At this point, the fire becomes ventilation-controlled, meaning the heat release rate is limited by the amount of oxygen available for combustion. Understanding this transition is essential for investigators to explain fire patterns and the speed of fire development leading to flashover.
Incorrect: Calculating the minimum ignition energy is relevant to the ease of ignition of a substance but does not govern the transition to a ventilation-controlled state in a fully developed fire. Determining specific heat capacity is important for understanding how materials absorb heat, but it is not the primary mechanism that limits fire growth in a compartment. Autoignition temperature is the lowest temperature at which a substance will spontaneously ignite without an external spark or flame; while relevant to ignition, it does not define the transition from fuel-controlled to ventilation-controlled combustion.
Takeaway: Accurate fire reconstruction requires identifying whether a fire was fuel-controlled or ventilation-controlled to understand how oxygen availability influenced the heat release rate and fire spread.
-
Question 10 of 10
10. Question
A whistleblower report received by a listed company alleges issues with Fire Resistance Testing and Materials Science during periodic review. The allegation claims that the internal engineering department approved the use of lightweight structural steel components in a high-rise project by extrapolating fire resistance ratings from tests performed on significantly heavier steel sections. The report, dated October 2023, suggests that the thermal response of the actual materials installed may differ substantially from the test data. Based on the principles of fire dynamics and heat transfer, why is the whistleblower’s concern regarding the extrapolation of fire resistance ratings from thick to thin structural members technically valid?
Correct
Correct: The surface area to volume ratio (A/V) is a critical factor in determining the fire resistance of structural elements. For a given material like steel, a thinner section has more surface area relative to its mass (volume) than a thicker section. Since heat is absorbed through the surface, the thinner member will heat up much faster than a thicker one when exposed to the same fire conditions. Consequently, the thinner member will reach its critical temperature (where it loses structural strength) much sooner, making extrapolation from thick to thin members unsafe and technically inaccurate.
Incorrect: Specific heat capacity is an intrinsic property of the material (energy required to raise the temperature of 1 kg by 1 degree) and does not change based on the thickness or geometry of the member. Thermal conductivity is also an intrinsic material property (k) that describes how heat moves through the substance; it does not change based on the cross-sectional area. Heat of combustion is a chemical property of a fuel and is not applicable to structural steel in this context, nor would it be affected by the thickness of the member.
Takeaway: The rate of temperature rise in a structural element is directly proportional to its surface area to volume ratio, meaning thinner components fail faster in fire conditions.
Incorrect
Correct: The surface area to volume ratio (A/V) is a critical factor in determining the fire resistance of structural elements. For a given material like steel, a thinner section has more surface area relative to its mass (volume) than a thicker section. Since heat is absorbed through the surface, the thinner member will heat up much faster than a thicker one when exposed to the same fire conditions. Consequently, the thinner member will reach its critical temperature (where it loses structural strength) much sooner, making extrapolation from thick to thin members unsafe and technically inaccurate.
Incorrect: Specific heat capacity is an intrinsic property of the material (energy required to raise the temperature of 1 kg by 1 degree) and does not change based on the thickness or geometry of the member. Thermal conductivity is also an intrinsic material property (k) that describes how heat moves through the substance; it does not change based on the cross-sectional area. Heat of combustion is a chemical property of a fuel and is not applicable to structural steel in this context, nor would it be affected by the thickness of the member.
Takeaway: The rate of temperature rise in a structural element is directly proportional to its surface area to volume ratio, meaning thinner components fail faster in fire conditions.